CO-DS1 (DS1 CO Trunk)
Issue 4 May 2002
10-435
555-233-123
FAIL
The trunk cannot be seized for an outgoing call. This could
cause in-line failures to be reported against the trunk (no
answer would report error type 257 with auxiliary data 57487 in
the error log).
1. Verify that the Trunk Type field on the trunk administration
screen form matches the trunk type administered on far
end switch.
2. Look for DS1-BD/UDS1-BD errors in Hardware Error Log.
If present, refer to the appropriate DS1-BD/UDS1-BD
(DS1/UDS1 Trunk Circuit Pack) Maintenance
documentation.
3. Retry the test at 1-minute intervals for a maximum of 5
times.
2000
FAIL
Response to the seizure message was not received within the
allowable time period.
1. Enter the list configuration board PCSS command. If the
circuit pack is a TN767B vintage 8 or 9, a failure of test
314 causes a subsequent failure of test 7 due to a
firmware bug. Eventually, the board and all of its ports will
be taken out of service and extraneous on-board alarms
will be generated. Replace the circuit pack with a TN767C
V3 or later.
2. Verify that the ’Trunk Type’ field on the ’Trunk
Administration’ screen matches the trunk type
administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error
log. If present, refer to the DS1-BD (DS1 trunk circuit pack)
maintenance documentation or to the UDS1-BD (UDS1
trunk circuit pack) maintenance documentation.
4. Retry the test at 1-minute intervals for a maximum of 5
times.
Table 10-162.
TEST #314 DS1CO Dial Tone Seizure Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...