Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-20
Issue 4 May 2002
CPE Alarm
Activation
Level
Indicates the minimum level (Major, Minor or Warning) to activate
Customer-Provided Equipment (CPE) alarm. If the level is none, the CPE
does not activate for any alarm.
NOTE:
When the switch goes into Emergency Transfer, the CPE alarm
activates regardless of the CPE Alarm Activation Level setting.
Packet Bus
Activated
If this field is set to yes, maintenance software assumes that a Packet Control
circuit pack is installed. If packet endpoints (for example, ASAI, and/or BRI)
are administered, and maintenance testing runs on both the Packet Control
circuit pack and Packet Bus, set this field to yes after a packet control circuit
pack is installed. If a Packet Control circuit pack is not installed in the system,
a major alarm is raised against the PKT-CTRL MO.
Change this field to no if no packet endpoints are administered, to ensure
that no packet endpoints can be administered if the packet bus deactivated.
If a Packet Control circuit pack is not installed, then this field should be set to
no (the only exception is system translations that do not have all required
hardware).
Customer Access
to INADS Port
To prevent customer login ID access to system administration and
maintenance interface control, set this field to no. Avaya services has sole
access to this field.
Repeat Dial
Interval (MMS)
Number of minutes that the system must wait before attempting another call
origination to an OSS. Lack of a far-end acknowledgment triggers the timer.
Scheduled Maintenance
Start Time
Hour and minute (24-hour notation) when daily scheduled maintenance starts
Stop Time
The hour and minute when scheduled daily maintenance ceases. If any daily
maintenance operations are not completed by this time, the system notes its
stopped sequence location and includes those operations during the next
scheduled daily maintenance.
Daily
Maintenance
This display-only field lists the standard test series run by maintenance software
during daily maintenance.
Save
Translation
Indicates days that translation data in memory automatically saves to the Mass
Storage System disk and/or tape devices during scheduled maintenance. The
operation saves to disk, then completes a backup to tape. Translation data
saves to both SPEs, if systems have duplicated SPEs. (daily, days of the week,
or no - prevents automatic saves)
Control
Channel
Interchange
Each port network has a pair of TDM busses (A and B). Each has a set of time
slots dedicated to the control channel. One bus at a time carries the control
channel in each PN. (daily, days of the week, or no - prevents interchanges).
(no)
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...