Maintenance Object Repair Procedures
555-233-123
10-186
Issue 4 May 2002
Table 10-60.
TEST #618 BRI Port Local LAN Looparound
Error
Code
Test
Result
Description/Recommendation
1015
ABORT
The port is not in the out-of-service state.
1. Display the Port Status form using the status bri-port
PCSSpp command to determine which stations or
adjuncts are on this port.
2. Use the extension shown on this form in the status
station command to determine if the station or adjunct is
in use.
3. If the port is in use, wait until it is idle, and use the busyout
port PCSSpp command to place it in the out-of-service
state and repeat this test.
!
WARNING:
Since the “busyout” command is destructive, using this
command prior to the port being idle causes all
transactions associated with the ASAI on the port to be
torn down. Note that third party calls established by an
ASAI adjunct remain connected even though the port is
taken out-of-service.
1139
ABORT
The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command and review the results of the BRI Port
Local LAN Looparound Test to verify the repair.
1141
ABORT
The PKT-CTRL is out-of-service.
1. Follow the repair procedures for the PKT-CTRL.
2. Issue the test port long PCSSpp command and review
the results of the BRI Port Local LAN Looparound Test to
verify the repair.
1144
ABORT
The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. Issue the test port long PCSSpp command and review
the results of the BRI Port Local LAN Looparound Test to
verify the repair.
2012
ABORT
Internal system error
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...