DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-641
555-233-123
1794
FAIL
The DS1 Interface circuit pack detects a Line Loopback Alarm
(LLB).
1. If the DS1 interface circuit pack connects to a T1 facility, call
the vendor of the T1 carrier to diagnose the remote DS1
endpoint.
2. If the DS1 interface circuit pack connects directly to a switch,
call the system technician of the remote switch to diagnose
the DS1 endpoint.
3. If the DS1 interface circuit pack connects directly to a
line-side terminating device (for example, a PRI terminal
adapter), call the vendor of the terminating device to
diagnose the equipment.
1795
FAIL
The DS1 Interface circuit pack detects a Payload Loopback
Alarm (PLB). If the DS1 Interface circuit pack connects to a
leased T1 facility, call the vendor of the T1 carrier to diagnose the
remote DS1 endpoint. If the DS1 Interface circuit pack connects
directly to another DS1 board, call the system technician of the
remote switch to diagnose the DS1 endpoint.
PASS
Remote DS1 endpoint is in-service. Neither a Blue alarm nor a
Line Loopback alarm nor a Payload Loopback alarm is detected
in the DS1 Interface circuit pack.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use
the add ds1 UUCSS command to administer the DS1
interface if it is not already administered.
2. If board was already administered correctly, check the error
log to determine if the board is hyperactive. If this is the case,
the board is shut down. Reseating the board will re-initialize
the board.
3. If the board was found to be correctly inserted in step 1, issue
the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the link between the internal ID and the
port.
Table 10-236.
TEST #139 Blue Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...