FAIL
The test failed because the data received did not match the
data sent. This would indicate that there is a fault somewhere
in the transmit/receive path to the TDM Bus, which probably
results in data corruption over this port. This test may fail if
Network Control Data Channel 3 is not functioning properly.
1. Look for DATA-CHL errors in the Error Log. If present,
refer to DATA-BD (Network Control Circuit Pack)
Maintenance documentation.
2. Repeat this test.
3. If the test fails again, replace the Data Line circuit pack.
2000
FAIL
The test failed waiting for the transmitted data to be looped
back.
1. Look for DATA-CHL errors in the Error Log. If present,
refer to DATA-BD (Network Control Circuit Pack)
Maintenance documentation.
2. Repeat this test.
3. If the test fails again, replace the Data Line circuit pack.
PASS
The port can correctly transmit/receive data. User-reported
troubles on this port should be investigated by examining the
ADU, external wiring, and customer equipment.
Table 10-189.
TEST #171 Digital Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...