Maintenance Object Repair Procedures
555-233-123
10-1458
Issue 4 May 2002
b. Error Type - 257 — A Keep-Alive Timer is set for every registered endpoint
on the Remote Office. The switch expects keep-alive update information
within a certain time period, and if that time limit is exceeded, an error is
logged. The error is a log-only error, because there is no way to determine
which entity has failed.
However, the aux data associated with this error indicates whether the
endpoint that failed to respond was a DCP, Analog, or Signaling Group
type.
■
Aux data with a value of (1096) = Analog Line
■
Aux data with a value of (1095) = DCP Line
■
Aux data with a value of (6179) = H.323 Signaling Group
System Technician-Demanded Tests: Descriptions
and Error Codes
There are no demand tests for this maintenance object, although the Remote
Office can be pinged using the ping ip/node command.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...