ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 4 May 2002
10-35
555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port PCSSpp command.
b. The circuit pack has been logically administered but not physically
installed. The alarm will be cleared when the circuit pack is installed.
c. The circuit pack has been removed or has been insane for more than 11
minutes. To clear the error, reseat or replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only one analog circuit pack in
the system has this problem, then replace the circuit pack. If only analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, check the ringing generator.
e. AUDIX is not available to the switch. Check the AUDIX system, referring to
EMBEDDED AUDIX System Maintenance, 585-300-110.
f. The TDM bus is out of service. See the “TDM-BUS” section.
Table 10-13. EMBEDDED AUDIX Analog Line/Control Link Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
1(a)
40977
None
18
0
busyout station
<extension>
WRN
ON
release station extension
23(b)
0
None
WRN
OFF
130(c)
None
WRN
ON
test port PCSSpp sh
257(d)
40973
None
513(e)
Any
None
1025(f)
Loop Around Test
(#161)
MIN/
WRN
2
2
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON
test port PCSSpp l r 2
1281
Conference Test (#7)
MIN/
WRN
2
ON
test port PCSSpp l r 2
1537
NPE Crosstalk Test (#6)
MIN/
WRN
2
ON
test port PCSSpp l r 2
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...