Maintenance Object Repair Procedures
555-233-123
10-1214
Issue 4 May 2002
Table 10-452.
TEST #6 NPE Crosstalk Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1000
ABORT
System resources required to run this test are not available.
The port may be in use on a valid call. Use status
pri-endpoint <extension> commands to determine when the
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1001
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM Bus errors. The status
health command can be used to determine if the system is
experiencing heavy traffic. Refer to TDM Bus Maintenance to
diagnose any active TDM Bus errors.
1. If system has no TDM Bus errors, and if it is not handling
heavy traffic, repeat the test at 1-minute intervals a
maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present, or some tone detectors may be out-of-service. The
list measurements tone-receiver command displays
information on the system’s tone receiver.
1. Look for TTR-LEV errors in the Error Log. If errors are
present, refer to TTR-LEV.
2. Look for TONE-PT errors in the Error Log. If errors are
present, refer to TONE-PT.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use status
pri-endpoint <extension> commands to determine when the
port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...