ANL-16-L (16-Port Neon Analog Line)
Issue 4 May 2002
10-83
555-233-123
1004
ABORT
The port was seized by a valid call during the test. The test has
been aborted. Use the display port PCSSpp command to
determine the station extension. Use the status station
command to determine the service state of the port. If the
service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle
before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005
ABORT
The test is not run because the port is administered as either
an External Alert or Announcement port.
1018
ABORT
The test has been disabled via administration. The default for
the ’Test’ field on the ’Station’ form is ’y’; thus, you may want to
determine why this field has been set to ’n’ on this station (this
may be due to the ringing application test 48, which can be
customer or terminal disturbing).
1. To enable the test for the particular analog station being
tested, enter change station extension and set the
‘Test?’ field on the station from 'n' to 'y.'
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-30. TEST #161 Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...