Maintenance Object Repair Procedures
555-233-123
10-1070
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 - indicates that the circuit pack has totally stopped functioning
or is not fully administered. The alarm is logged about 15 minutes after the
circuit pack has been removed or 11-minutes after the
SAKI
Test (#53) fails.
To be fully administered, a MedPro circuit pack must meet all of these 4
conditions:
1. Have an entry in the circuit pack form (change circuit pack)
2. Have the MedPro IP address administered (change node-names)
3. Be enabled (change ip-interface)
Table 10-397.
DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test board UUCSS
1(a)
0
Circuit pack removed or SAKI
Test (#53)
MIN/WRN
2
2
If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the
circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been
missing for a period of 15 minutes. Warning alarms are also raised against any ports administered
on the circuit pack.
ON
18(b)
0
busyout board UUCSS
WARNING
OFF
release board UUCSS
23(c)
0
WARNING
OFF
add ds1 UUCSS
125(d)
None
None
MIN/WRN
3
3
Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
ON
257(e)
65535
Control Channel Loop Test
(#52)
MINOR
ON
test board UUCSS l r 2
1538(f)
Any
Hyper activity
MIN/WRN
ON
1793
Any
NIC Loss Of Signal
MIN/WRN
test board UUCSS l r 2
2049(g)
Any
NT PC Failure
MIN/WRN
reset board UUCSS
2305
Any
IP Address Inconsistency
test board UUCSS l r 2
2561
Any
Ping Error
MIN/WRN
test board UUCSS l r 5
3841(h)
4358
Log Only
3999(i)
Any
None
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...