Maintenance Object Repair Procedures
555-233-123
10-966
Issue 4 May 2002
3903
Service or option not
available, unspecified. This
cause is used to report a
service or option not
available event only when
no other cause in the
service or option not
available class applies.
3905
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
If customer is complaining of unexpected
intercept tones when accessing ISDN trunks
or PRI endpoints and no other cause can be
found, provide the next tier with this Error
Log information.
3906
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
If customer is complaining of unexpected
intercept tones when accessing ISDN trunks
or PRI endpoints and no other cause can be
found, provide the next tier with this Error
Log information.
3909
A request to use a network
service has been made, but
the network has rejected
the request because the
requested service is not
implemented.
Follow the recommendations listed above for
error type 3890.
3910
Only restricted digital BC
available.
3919
Service or option not
implemented, unspecified.
Used when no other cause
in this class applies.
Table 10-349.
Descriptions of Error Codes 3842-3942 — Continued
Error
Code
Description
Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...