Maintenance Object Repair Procedures
555-233-123
10-832
Issue 4 May 2002
8
FAIL
The announcements are different in both SPEs. The Active
SPE has the most current announcements.
1. Issue save announcements to save announcements
in both SPEs. If the announcement save passes on
both SPEs, go to Step 2.
2. Run test card-mem long to resolve the alarms.
9
FAIL
The translations and announcements are different in both
SPEs. The Active SPE is the most current.
10
FAIL
The translations and announcements are different in both
SPEs. The Standby SPE has the most current translations,
and the Active SPE has the most current announcements.
1. Issue the save translations command to save
translations in both SPEs.
2. Issue the save announcements command to save
announcements in both SPEs.
3. If the translation save and announcement save pass
on both SPEs, run test card-mem long to resolve the
alarms.
12
FAIL
Load vintages and announcements are different in both
SPEs. The Active SPE has the most current
announcements.
1. Follow the procedures for Error Codes 4 and 8.
13
FAIL
The translations, announcements, and load vintages are
different in both SPEs. The Active SPE has the most
current translations and announcements.
1. Follow the procedures for Error Codes 4 and 10.
14
FAIL
The translations, announcements, and load vintages are
different in both SPEs. The Standby SPE has the most
current translations, and the Active SPE has the most
current announcements.
1. Follow the procedures for Error Code 4. Run save
announcements.
16
FAIL
Announcements are different in both SPEs. The Standby
SPE has the most current announcements.
1. Follow the procedures for Error Code 8.
Table 10-303.
TEST #421 Flash Data Consistency Check Test — Continued
Error Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...