ETR-PT (Enhanced Tone Receiver Port)
Issue 4 May 2002
10-755
555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the Tone
Detection Verification Test, for example, you may also clear errors generated from
other tests in the testing sequence.
Tone Detection Verification Test (#42)
This test checks out a single ETR port in the touch-tone receiver mode MFC tone
detection/generation mode and general purpose tone detection mode. During the
first portion of the test, the touch-tone receiver mode is tested. Then general
purpose call progress and maintenance tones are tested and lastly MFC tones are
tested.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
Tone Detection Verification Test (#42)
X
X
ND
Tone Detection Audit/Update Test (#43)
X
X
ND
Table 10-285.
TEST #42 Tone Detection Verification Test
Error
Code
Test
Result
Description/Recommendation
none
ABORT
The system was not able to allocate all the resources needed
for this test OR there was an Internal System Error.
1
ABORT
The system could not allocate all the resources needed to test
the tones.
1001
ABORT
The system was unable to put the ETR-PT in the appropriate
mode to test it.
1002
ABORT
The system could not allocate time slots for the test
connection. This situation could occur when the system is
heavily loaded. If the system is not heavily loaded, then test
the TDM-BUS via the test tdm command. Refer to TDM-BUS
for details.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...