
PR-MAINT (Maintenance Processor)
Issue 4 May 2002
10-1395
555-233-123
Table 10-518.
TEST #104 MTP Dual Port Ram Test
Error
Code
Test
Result
Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
(Refer to STBY-SPE Maintenance documentation for a
description of these error codes.)
1000
ABORT
System software resources required to run this test are not
available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1030
ABORT
The component on which the test was to be run is on the
Standby SPE. This test may be run on this component only
when it resides on the Active SPE.
1. For a recommended maintenance procedure, refer to
ABORT Error Code 1030 in STBY-SPE Maintenance
documentation.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2028
ABORT
System software resources required for this test are not
available.
2029
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL
The dual port RAM is not functioning correctly.
Communication between the processor and MTP is lost. The
system is not able to report environmental alarms,
communicate with the Standby SPE, or reboot from tape, if
necessary.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, replace the Processor circuit
pack.
PASS
Dual port RAM is functioning. Communication exists between
the 80286/386 Processor circuit pack and the MTP.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...