Maintenance Object Repair Procedures
555-233-123
10-866
Issue 4 May 2002
e. Error Type: 769 — indicates that a downloadable board image is bad and
a good image needs to be downloaded. This is not a result of a failed
download attempt. The Aux Data specifies the board location in UUCSS
format.
System Technician-Demanded Tests:
Descriptions and Error Codes
The Firmware Download Maintenance Object (FW-DWNLD) is a non-traditional
MO. As a result, the associated test, Test Firmware Download (#1413) is a
non-traditional test. This test is not executed in the traditional manner but is
executed as a part of scheduling, verifying, and running a firmware download
schedule.
There are no System Technician demand tests as such for this maintenance
object.
Test Firmware Download (#1413)
This is a destructive test.
This test has two functions and can only be executed if there is a download
schedule to verify or there are FW-DWNLD errors to be resolve and alarms to
clear.
1. This test verifies that the information on the FIRMWARE DOWNLOAD
screen is correct. It also verifies that the source board is of the correct type,
that the file to be downloaded is present on that source board, and that the
file is error free. In addition it verifies that the target board code and suffix
are correct. It also retrieves the new firmware vintage for the target board
and populates the appropriate field in the firmware download table.
2. If this test is executed after a FIRMWARE DOWNLOAD schedule has run,
and there are FW-DWNLD alarms/errors, it resolves the errors, clears the
alarms, copies the current download status table to the last table, and
clears out the current table.
Table 10-312.
TEST #1413 Firmware Download Test
Error
Code
Test
Result
Description/ Recommendation
ABORT
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
2100
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...