Maintenance Object Repair Procedures
555-233-123
10-1312
Issue 4 May 2002
2500
ABORT
Internal system error
1. Retry the command at 1-minute intervals, a maximum of 5
times.
NO
BOARD
The Packet Interface is not detected as being physically
present.
1. Reboot the system, then retry the command. If the NO
BOARD indication persists, replace the TN2401/TN794
NetPkt circuit pack.
1-3
FAIL
The test failed. Maintenance was unable to establish a
looparound link from the Packet Interface back to itself or was
unable to receive data that was sent out over one side of the
looparound link.
1. Issue the test packet-interface CS command to retry the
test. If the same error code is observed, background
maintenance software will automatically attempt to reset the
circuit pack and clear the problem.
2. Retry the command and if the test fails, replace the
TN2401/TN794 NetPkt circuit pack.
3. If the test continues to fail after replacing the
TN2401/TN794 NetPkt circuit pack, run the test packet P
long command. If any of the tests fail, the fault may be on
the Packet Bus. Refer to the PKT-BUS (Packet Bus)
Maintenance documentation for recommended repair
procedures.
4. If the test continues to fail after the TN2401/TN794 NetPkt
circuit pack is replaced and with no other alarms associated
with the Packet Bus or circuit packs connected to the
Packet Bus, follow normal escalation procedures.
PASS
This test passed. The Packet Interface and its interface with the
SPE are functioning properly. If the system is unable to place
calls on cabinets other than the SPE cabinet, then:
1. Check for errors on the Packet Bus and Maintenance/Test
circuit pack. Solve those errors first.
2. Check all other circuit packs connected to the Packet Bus in
the same cabinet. Packet Bus failures are likely to be
caused by a faulty circuit pack connected to the backplane
or bent pins on the back plane.
3. Check the TN2401/TN794 NetPkt circuit pack connections
to the Packet Bus.
Table 10-486.
TEST #886 Maintenance Looparound Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...