M/T-PKT (Maintenance/Test Packet Bus Port)
Issue 4 May 2002
10-1159
555-233-123
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. This error indicates a hardware failure with the port circuitry which provides
the Packet Bus maintenance functions. Replace the Maintenance/Test
circuit pack if the alarm is not resolved by the test command above.
b. The port has been busied out via the busyout port PCSSpp command.
c. This error indicates that the Maintenance/Test Packet Bus Port has
reconfigured the Packet Bus (that is, swapped a bad lead to a spare). Note
that this error is sent up whenever the Maintenance/Test Packet Bus Port is
initialized (since the Packet Bus Port reconfigures the Packet Bus to
whatever state it determines the Packet Bus is in). This occurs if the circuit
pack is inserted, if the system is restarted, or if the port is released from a
busyout state. Therefore, it is normal for this error to be present in the error
log.
If the Maintenance/Test Packet Bus Port reconfigures the Packet Bus 12
times within 15 minutes, a Minor alarm is raised. When the Minor alarm is
raised, this is an indication that the Packet Bus maintenance functions are
not operating correctly, or that many changes are taking place on the
Packet Bus (that is, circuit pack insertion or removal). If the system has
been in a stable state for more than 15 minutes, try the following
procedures:
1. Reset the Maintenance/Test circuit pack from the Manager I
terminal, as follows:
■
Enter the busyout board PCSS command.
■
Enter the reset board PCSS command.
■
Enter the release board PCSS command.
M/T-PKT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp
1 (a)
41018
none
MINOR
ON
test port PCSSpp l r 3
18 (b)
0
busyout port PCSSpp
WARNING
OFF
release port PCSSpp
257 (c)
Any
none
MINOR
ON
513 (d)
Any
Packet Bus Port Health
Inquiry Test (#567)
MINOR
ON
test port PCSSpp r 3
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...