Maintenance Object Repair Procedures
555-233-123
10-874
Issue 4 May 2002
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the
CLAN Ethernet
Status Test (#1386)
, for example, you may also clear errors generated from other
tests in the testing sequence.
CLAN Ethernet Status Test (#1386)
This test is non-destructive.
This test checks the status of the CLAN ethernet port that originated this signaling
group. If the CLAN ethernet port is in-service, the test passes; if it is out of service
(OOS), the test fails.
NOTE:
Failure of this test will put the SIG-GRP in the OOS state.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
CLAN Ethernet Status Test (#1386)
X
X
ND
MedPro Status Test (#1392)
X
X
ND
H.323 Signaling Group Ping Test (#1387)
X
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...