Maintenance Object Repair Procedures
555-233-123
10-1932
Issue 4 May 2002
The list measurements ds1 summary command will display the length of time
the test ran (
Test Duration
field) and number of bit errors detected
(
Loopback/Span Test Bit-Error Count
field).
To restore the trunks or ports on the UDS1 Interface circuit pack to the in-service
state, execute release board.
Table 10-689.
TEST #1216 End Loopback/Span Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS end-loopback/span-test
command at 1-minute intervals a maximum of 5 times.
1005
ABORT
End Loopback/Span Test cannot be executed in the current
configuration. To run this test, the TN464F or later suffix DS1
board must be administered for 24-channel operation. The “Bit
Rate” field on the DS1 circuit pack administration form must be
set to “1.544” for 24-channel operation.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied
out to out-of-service.
1. Enter the busyout board UUCSS command to put all trunks
or ports of the UDS1 Interface circuit pack into the
out-of-service state.
2. Retry the command.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...