Maintenance Object Repair Procedures
555-233-123
10-1110
Issue 4 May 2002
5001
ABORT
A Network Control Channel could not be allocated for this test.
This error is more closely related to the Data Channels (1 or 3
only) on the DATA-CHL circuit pack used for this test than the
TN758 Pooled Modem circuit pack itself. Therefore, any
hardware testing or replacement activities focus on the
DATA-CHL circuit pack. However, the Data Channels on the
DATA-CHL circuit pack normally should not be busied out,
tested with the test data-module command, or reseated in the
carrier to clear this error, since this may drop other data calls
that may be active at the time. The administration of Data
Channels 1 and 3 should be checked if this error occurs.
1. Wait one minute and attempt the test again.
2. If the same error persists after five attempts at one-minute
intervals, escalate the problem.
5002
ABORT
The Network Control Channel allocated for this test could not
be set to “maintenance busy” status.
1. Follow the repair procedures for Error Code 5001.
5003
ABORT
The test was not able to establish a connection for the digital
portion of the Modem Pool Port.
1. Follow the repair procedures for Error Code 5000.
5004
ABORT
The test was not able to allocate the analog portion of the
Modem Pool Port.
1. Follow the repair procedures for Error Code 5000.
5005
ABORT
The test was not able to establish a connection for the analog
portion of the Modem Pool Port.
1. Follow the repair procedures for Error Code 5000.
Table 10-417.
TEST #98 Modem Pool Conversion Resource Loop Around Test
— Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...