busyout link
Issue 4 May 2002
8-9
555-233-123
busyout link
This command places maintenance objects associated with a specified link in a
maintenance busy state. No periodic or scheduled tests are performed on the
busied out maintenance objects until they are released. The link is marked out of
service and is inaccessible to call processing. Warning alarms (error type 18) are
generated on each busied out maintenance object, so that INADS can determine
the state of the objects. The release link command reactivates the objects.
Output
The following example shows the output from the busyout link 1 command. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
busyout
link
link-id
Processor Interface circuit
pack 1a1 or 1b1 = 1 – 4
Processor Interface circuit
pack 1a2 or 1b2 = 5 – 8
Examples
busyout link 1
init
inads
craft
none
none
Port
Port address represents link-id
Maintenance Name
The name of the busied out maintenance object
Alt. Name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
busyout link 1 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C0301 PI-LINK PASS
Command successfully completed
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...