ADX16A-PT (AUDIX Analog Line/Control Link)
Issue 4 May 2002
10-39
555-233-123
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly
perform the conferencing function.
Table 10-15. TEST #7 Conference Circuit Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
(a)
1000
ABORT
System resources required to run test are not available. The port
may be busy with a valid call.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before
retesting.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has
been aborted.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before
testing.
3. When the port is idle, retry the command at 1-minute
intervals a maximum of 5 times.
1018
ABORT
Test disabled by administration. This only applies to analog
stations.
1. To enable the test for the analog station being tested, enter
the change station <extension> command and change the
Test?
field on the Station Form from
n
to y.
2000
ABORT
Response to the test request was not received within the
allowable time period.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...