E-DIG-STA (Emulated Digital Line)
Issue 4 May 2002
10-727
555-233-123
1004
ABORT
The port was seized by a valid call during the test.
1. Use display port PCSSpp to determine the station
extension or attendant number of the port.
2. Use status station or status attendant to determine the
service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain
tests.
3. Wait until the port is idle before retesting. Attendants are
always in use (off-hook) if the handset is plugged in and the
port is not busied out.
1020
ABORT
Test disabled by background testing. Use the status station
command to determine when the station is available for testing.
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
2
FAIL
The Network Processing Element (NPE) of the tested port is
transmitting in error. This causes noisy and unreliable
connections.
Failure code 1 indicates that the Crosstalk test failed on the
primary channel.
Failure code 2 indicates that the Crosstalk test failed on the
secondary channel.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To ensure that this is not an intermittent problem, repeat
this test a maximum of 10 times.
2. If complaints persist, examine the station, connections, and
wiring.
Table 10-271.
TEST #9 Digital Line NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...