Maintenance Object Repair Procedures
555-233-123
10-440
Issue 4 May 2002
Notes:
a. These are in-line errors that have no specific test associated with them.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
c. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
d. Aux data 57345 -- Single polarity ringing current
Aux data 57376 -- No loop current on incoming call
Aux data 57408 -- No tip ground detected on outgoing call
Aux data 57424 -- No loop current on outgoing call
Aux data 57484 -- No dial tone on outgoing call
2049
NPE Cross Talk Test
(#6)
MAJ/MIN/
WRN
2
ON
test port PCSS l r 3
2561 (d)
57345
None
2817 (a)
57360
None
2817 (a)
57393
None
2817 (d)
57484
Dial Tone Test (#0)
MAJ/MIN/
WRN
2
OFF
test port PCSS l r 1
3073 (d)
57376
None
3329 (d)
57408
None
3329 (d)
57484
Dial Tone Test (#0)
MAJ/MIN/
WRN
OFF
test port PCSS l r 1
3585 (d)
57424
None
3840 (f)
8000
Analog Transmission
(#844-848)
OFF
3841 (f)
Analog Transmission
(#844-848)
MINOR
OFF
test analog testcall UUCSS
pp r 2
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm
is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Table 10-163.
CO Trunk Error Log Entries — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...