Maintenance Object Repair Procedures
555-233-123
10-1924
Issue 4 May 2002
One-Way Span Test (#1214)
This test is destructive.
The One-Way Span Test allows one-way span testing to and from remote test
equipment or another DEFINITY communications system. This tests all circuitry
and facilities from the local DS1 board to the remote test equipment or other
DEFINITY communications system.
The test is destructive and can only be initiated by a system technician demanded
test ds1-loop UUCSS one-way-span-test-begin command.
All trunks or ports on the UDS1 Interface circuit pack must be busied out using the
system technician busyout board command before running the One-Way Span
Test.
PASS
The Far CSU Loopback test has successfully began executing.
The test will continue to run until the system technician enters the
test ds1-loop UUCSS end-loopback/span-test command or
the release board UUCSS command.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the
add ds1 UUCSS command to administer the UDS1 interface
if it is not already administered.
2. If the board was already administered correctly, check the
error log to determine whether the board is hyperactive. If
this is the case, the board is shut down. Reseating the board
will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then
issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Table 10-686.
TEST #1213 Far CSU Loopback Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...