Maintenance Object Repair Procedures
555-233-123
10-1002
Issue 4 May 2002
2067
ABORT
The call has timed out, perhaps because of a lack of system
resources.
1. Follow the recommendations for ABORT code 2035.
2074
ABORT
Bit and Block Error query failed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, there may be a serious
internal problem with Maintenance/Test Digital Port.
2075
ABORT
Internal system error
1. Follow the recommendations for ABORT code 2012.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2104
ABORT
Call dropped or could not be originated.
1. Make sure service is provisioned by the network.
2. Check the administration of the far-end test line extension
on the trunk group administration form.
3. Check the administration of the test call BCC (Bearer
Capability Class) on the trunk group administration form.
4. Check the reason for termination with status
isdn-testcall.
5. For further instructions see “Troubleshooting ISDN-PRI
Test Call Problems” in
Chapter 5, ‘‘Routine Maintenance
6. Try the test again.
2201
2202
2203
2204
2205
ABORT
Internal system error
1. Follow the recommendations for ABORT code 2012.
2206
ABORT
Could not allocate the necessary system resources to run this
test.
1. Follow the recommendations for ABORT code 2100.
2208
ABORT
Internal system error
1. Follow the recommendations for ABORT code 2012.
Table 10-363.
TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...