PI-LINK (Processor Interface Link)
Issue 4 May 2002
10-1247
555-233-123
ISDN Hardware Check Test (#234)
This test checks the status of the ISDN hardware which is the DS1 Interface
circuit pack and cabling. Status of the DS1 port is kept by the system. The state of
the port can be in-service or out-of-service. This state is updated by DS1 Interface
circuit pack maintenance. If DS1 maintenance detects a problem with the physical
medium near-end or far-end, the Processor Interface Link maintenance is
instructed to restart the link. Therefore, if this test fails, the port is considered
out-of-service and the link cannot be brought up until DS1 maintenance changes
the state to in-service. This is more of a status inquiry than a test. Thus, the only
recovery procedure is to refer to DS1-BD (DS1 Trunk Circuit Pack) Maintenance
documentation.
Table 10-464.
TEST #234 ISDN Hardware Check Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the test at 1-minute intervals a maximum of 5 times.
1005
ABORT
This test only runs for ISDN-PRI links. This link is a BX.25 link
and, thus, aborts.
FAIL
Indicates that there is a physical problem with the DS1 facility link.
1. Cross-reference DS1 Interface circuit pack errors for possible
reason. Refer to “DS1-BD”.
2. Retry the test. It continues to fail until the DS1 problem is
cleared up.
PASS
DS1 facility is functioning correctly.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...