Maintenance Object Repair Procedures
555-233-123
10-1866
Issue 4 May 2002
FAIL
UDS1 Interface circuit pack detects a Loss of Signal alarm. The
physical link is broken or the remote DS1 endpoint is down. All
trunks or ports of this UDS1 interface circuit pack are
out-of-service. If the UDS1 Interface circuit pack is designated as
the supplier of the system synchronization source, then the
system synchronization maintenance will adopt a source
elsewhere. Refer to the
section in
this chapter for details. If the UDS1 connects to a T1 network
facility:
1. Check the physical connection of the UDS1 Interface circuit
pack and the cable. If a CSU Module or a Sync Splitter is
physically connected to a UDS1-BD board on the back of the
port carrier, check the physical connection of the CSU
Module/Sync Splitter and make sure the Network Interface
cable is plugged into the CSU Module’s/Sync Splitter’s
NETWORK jack.
2. If the UDS1 Interface circuit pack connects to a T1 facility, call
the vendor of the T1 carrier to diagnose the remote DS1
endpoint. If the UDS1 Interface circuit pack connects directly
to a switch, call the system technician of the remote switch to
diagnose the DS1 endpoint.
If the UDS1 connects to a line-side terminating device such as a
PRI terminal adapter:
1. Check the physical connection of the UDS1 Interface circuit
pack to the terminating device. Check premise distribution
system (or intra-premise wiring) for physical connection
failures. If a CSU Module or Sync Splitter is physically
connected to a UDS1-BD board on the back of the port
carrier, check the physical connection of the CSU
Module/Sync Splitter and make sure the Network Interface
cable is plugged into the CSU Module’s/Sync Splitter’s
NETWORK jack.
2. Contact the vendor of the line-side terminating device to
diagnose the equipment.
Table 10-673.
TEST #138 Loss of Signal Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...