UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1897
555-233-123
1 to
88
(cont.)
FAIL
(cont’d.)
If the UDS1 connects to a line-side terminating device (for
example, a PRI terminal adapter), do the following:
1. Retry the command at 1-minute intervals for a maximum of 5
times.
2. Enter the list measurement ds1-log UUCSS command to
read the error seconds measurement.
3. Verify that the switch DS1 and the line-side terminating
device are administered using the same signaling mode,
framing mode, and line coding.
4. Investigate the maintenance status of the line-side
terminating device. Refer to the ’Line-Side Terminating
Device Operating Manual’ for information.
5. Contact the vendor of the line-side terminating device to
diagnose the equipment.
6. Check the physical connection of the UDS1 interface circuit
pack to the terminating device, and check the premise
distribution system (or the intra-premise wiring) for physical
connection failures.
7) Replace the local UDS1 interface circuit pack and repeat the
test.
PASS
No Slip alarm is detected on the UDS1 Interface circuit pack.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the
add ds1 UUCSS command to administer the UDS1 interface
if it is not already administered.
2. If the board was already administered correctly, check the
error log to determine whether the board is hyperactive. If
this is the case, the board is shut down. Reseating the board
will re-initialize the board.
3. If the board was found to be correctly inserted in step 1, then
issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Table 10-679.
TEST #144 Slip Alarm Inquiry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...