ANN-PT (Announcement Port)
Issue 4 May 2002
10-161
555-233-123
number, the more severe the problem with that port. If this test fails,
announcements played over this port should sound corrupted.
Table 10-53. TEST #206 Playback Speech Memory Array (PSMA) Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
The port may be in use on a valid call.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the pack is not in use,
escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
“TDM-BUS (TDM Bus)” Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat the test at 1-minute intervals a
maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to “TTR-LEV (TTR Level)” Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to “TONE-PT (Tone Generator)” Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
1024
ABORT
Announcement circuit pack blocked the test because an
announcement download is in progress. If an announcement
download is in progress, a status data-module
<announcement data extension> command should show
that the announcement data port is connected to a NETCON
data channel, and the tape drive should be active. (To
determine the extension of the announcement data module,
use the list data-module command.)
See Note (a) at end of table for more information.
1. Wait until download is finished (could take a maximum of
45 minutes), and then run the test again.
2. If the test continues to abort and there is no download in
progress, escalate the problem.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...