DUPINT (Duplication Interface Circuit Pack)
Issue 4 May 2002
10-707
555-233-123
The following table summarizes the Aux Data fields.
c. An Aux value of blank or 65317 is valid. The 65317 Aux value means the
Duplication Interface circuit pack reported the trouble, while the blank
means the software detected the trouble.
d. This could be caused by mismatched numbers of Processor Interface,
Packet Control, or NetPkt circuit packs in the two SPEs or by a defective
Duplication Interface circuit pack. If the Duplication Interface circuit pack is
defective and becomes part of the Standby SPE, then memory shadowing
does not work. Follow the procedures given for the FAIL case of Common
Shadow Circuit M-Bus Time-Out Query Test (#285) in the SHDW-CIR
section.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are presented in the table below. By
clearing error codes associated with the Duplication Interface Circuit Pack Status
Query Test, for example, you may also clear errors generated from other tests in
the testing sequence.
For example, you may also clear errors generated from other tests in the testing
sequence.
Aux
Data
Description
1 or
3
Duplication Interface circuit pack A lost handshaking with Duplication
Interface circuit pack B.
2
MTP lost handshaking with the Duplication Interface circuit pack.
221
Duplication Interface circuit pack reported the trouble.
65315
or
65503
Duplication Interface circuit pack A lost contact with Duplication
Interface circuit pack B.
Blank,
65313,
or
65501
If reported against Duplication Interface circuit pack A, Duplication
Interface circuit pack A lost handshaking with Maintenance/Tape
Processor A.
If reported against Duplication Interface circuit pack B, Duplication
Interface circuit pack A lost handshaking with Maintenance/Tape
Processor B.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...