
Maintenance Object Repair Procedures
555-233-123
10-1580
Issue 4 May 2002
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE for a description of these error codes
0
FAIL
The Switch Control cannot communicate on the TDM Bus
control channel. The customer probably cannot make or
receive calls.
1. Run the Short Test Sequence several times to make sure
this failure is occurring consistently, run the Long Test
Sequence to reset the Switch Control. Sometimes,
running the Long Test Sequence may clear the problem.
Remember that the Long Test Sequence is destructive.
Placing and receiving calls is affected for several
seconds.
2. If there are no TDM Bus alarms against the Standby TDM
Bus, switch the control channel from its current bus to the
Standby bus. If this test passes on the new bus,
investigate the possibility of TDM Bus failures. If the test
fails even after the control channel is switched to the
standby TDM Bus, proceed to Step 3 3 or 4.
3. If the system is still able to process calls, replace the
NetPkt or Netcon circuit pack at the customer’s
convenience (Standard system) or right away (High or
Critical Reliability system).
4. If calls cannot be made, replace the NetPkt or Netcon
circuit pack immediately.
PASS
The Switch Control can communicate with the port circuit
packs over the TDM Bus.
Table 10-584.
TEST #94 Control Channel Transmission Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...