PDMODULE, TDMODULE (Data Module)
Issue 4 May 2002
10-1201
555-233-123
1074
FAIL
Internal System Error.
1. Make sure that the data equipment connected to the data
module is powered.
2. For an (M)PDM, verify that the Data Terminal “Ready” LED
is ON, or for an (M)TDM, verify that the Data Set Ready
LED is ON. If it is not on, check the cable from the data
equipment to the data module.
1075
FAIL
Unknown message received during test.
1. Attempt the test again.
2. If the same error occurs, test the Network Control Data
Channel using the test data-module command and a
known working data module.
3. Replace the Digital Line circuit pack and repeat the test.
4. If the test continues to fail, escalate the problem.
2040
FAIL
Internal System Error.
2095
FAIL
Internal System Error.
1. Repeat the test.
PASS
Data Module Loop Around Test passed. This digital port circuit
pack is functioning properly.
1. If problems persist, investigate by using other port tests and
by examining the data module options, wiring, and
connections.
Table 10-448.
TEST #175 Data Module Internal Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...