Maintenance Object Repair Procedures
555-233-123
10-1296
Issue 4 May 2002
For the case where not all links are in the “Failed Links” category, examine
the alarm log and error log for failures of the following circuit pack types
and follow the repair procedures for those circuit packs before considering
replacing the TN2401/TN794 NetPkt associated with a suspect Packet
Interface:
■
Expansion Interface circuit pack (EXP-INTF)
■
ISDN-BRI Line circuit packs, ports, and stations (BRI-BD,
BRI-PORT, BRI-SET, ATT-PORT, ATT-ADJ, )
■
ISDN-BRI Trunk circuit pack and ports (TBRI-BD, TBRI-PT)
■
Universal DS1 circuit packs and ports (UDS1-BD, TIE-DS1)
■
DS1 Interface circuit packs and ports (DS1-BD, TIE-DS1)
■
C-LAN circuit packs and ports (CLAN-BD, RSCL-PT, PPP-PT,
ETH-PT)
■
ASAI circuit packs and ports (ASAI-BD, ASAI-PT, ASAI-ADJ,
ASAI-EPT, LGATE-BD, LGATE-PT, LGATE-AJ, ATTE-PT, ATTE-AJ,
MAPD-BD)
■
Media Processor circuit pack (MEDPRO, MEDPRO-RES)
Error Log Entries and Test to Clear Values
Table 10-483.
Packet Interface Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
1
0
2
0
Any
Any
ON
test packet-interface 1CS r 2
1 (a)
Any
None
MAJOR
3
ON
reset io-processor
4
10 (b)
0
None
23 (c)
0
None
MAJOR
3
OFF
50 (d)
0
None
100 (e)
0
None
217 (g)
0
None
WARNING
OFF
257 (f)
Any
None
MAJOR
3
ON
reset io-processor
4
267 (g)
0
None
WARNING
OFF
513 (h)
Any
None
MAJOR
3
ON
reset io-processor
4
769
5
(i)
Any
Mtce Looparound
Test (#886)
5
MAJOR
3
ON
test packet-interface 1CS r 3
1025 (j)
Any
Private Looparound
Test (#885)
MAJOR
3
ON
reset packet-interface 1CS
4
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...