SAKI Sanity Test (#53)
This is a destructive test.
This test is only run as a part of a reset board procedure. For the Media
Processor, it is necessary to use the change ip-interfaces form to disable the
Media Processor IP interface before performing this reset board procedure. Other
common circuit packs can be reset with the reset board UUCSS command which
also executes this test.
A reset of this circuit pack will take about 3 1/2 minutes.
Table 10-400.
TEST #53 SAKI Sanity Test
Error
Code
Test
Result
Description/Recommendation
None
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
1015
ABORT
Port is not out-of-service.
1. Busy out the circuit pack.
2. Execute command again.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
2803
ABORT
It is necessary to reset the board.
1. Use the change ip-interfaces form to disable the Media
Processor IP interface.
2. Execute the command again.
1
FAIL
The circuit pack failed to reset.
2
FAIL
The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...