Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-274
Issue 4 May 2002
All successful reset system commands log users off.
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
reset system
level
interchange
health-override
See below
Examples:
reset system 1
reset system 2
reset system interchange
health-override
init
inads
craft
none
see below
level
Reset levels are entered numerically:
1 = Warm Restart
2 = Cold-2
3 = Cold1
4 = Reboot
5 = Extended Reboot
interchange
System control passes to standby SPEs as active and standby SPEs
change roles. The optional “health-override” qualifier can be entered
to bypass Fault Severity Levels of standby SPEs to force an
interchange. SPE alarm components determine Fault Severity levels.
Each component is assigned a severity level, and the most severe
SPE alarm defines Fault Severity Levels for SPEs. The following table
lists maintenance objects, their alarms, severities and interchange
restart levels that affect SPE Fault Severity Levels.
Maintenance
Object
Alarm Level
On/Off
Board
Fault Severity
Level
Restart
Level
STBY-SPE
WARNING
OFF
120
None
MEM-BD
MAJOR or MINOR
ON
110
Hot or Warm
MEMORY
MAJOR or MINOR
ON
110
Hot or Warm
STBY-SPE
MAJOR
ON
100
None
PROCR
MAJOR
ON
70
Hot or Warm
SW-CTL
MAJOR
ON
65
Cold 2
MEM-CARD
MAJOR
OFF
65
Cold 1
DUPINT
MAJOR
ON
61
Hot
CARR-POW
MAJOR
ON
61
Cold 2
SHDW-CIR
MAJOR
ON or OFF
60
Warm
SHDW-LINK
MAJOR
ON
60
Warm
SW-CTL
MINOR
ON
40
Hot
PR-MAINT
MINOR
ON
30
Hot
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...