Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-124
Issue 4 May 2002
Test Type
One of the following types of test to be performed on the trunk
group/members in this schedule:
■
full runs the most comprehensive test and collects all associated
measurements for each TTL type.
■
supv performs a supervision test and only confirms the presence of
the test set at the far end. No measurements are taken for this test.
■
no-st runs the “full” test, but skips any self-test sequences. This
saves about 20 seconds on the type 105 test and does not have
any effect on type 100 or 102 tests.
■
no-rl runs the “full” test, but skips any return loss sequences. This
saves about 20 seconds on the type 105 test and does not have
any effect on type 100 or 102 tests.
■
no-st/rl runs the “full” test, but skips all self-test and return loss
sequences. This saves about 40 seconds on the type 105 test and
does not have any effect on type 100 or 102 tests.
Duration
The maximum number of hours (1 to 24) a schedule can remain active.
Schedules continue to run until all trunk group/members for that
particular schedule are tested or until the schedule duration is reached.
If the duration is reached before all trunk groups/members can be
tested, the schedule stops.
Trk Trp
The trunk group numbers to be tested when this schedule runs. There is
no limit to the number of times that a trunk group can appear on any
particular schedule, or to the number of different schedules in which a
trunk group can appear. Default is blank.
Bgn Mbr
The beginning member number of the trunk group to be tested; default
is 1.
End Mbr
The ending member number of the trunk group to be tested. This value
must be greater than or equal to the value of the beginning member
field.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...