Maintenance Object Repair Procedures
555-233-123
10-1046
Issue 4 May 2002
d. Try pinging another device on the same subnet.
e. Try pinging the gateway to the rest of the network from the subnet.
f. Try pinging a device not on the local subnet but on the network or
another subnet.
5. When finished, at the command prompt type exit and press
Enter
.
Internal connections to the LAN
Test the internal connections to the LAN by pinging the
■
local host
■
internal IP trunk server
■
another device connected to the network:
1. Click Start in Windows (lower lefthand corner), then select Programs, then
Command Prompt.
This starts a DOS command line session.
2. At the command prompt, type ping 127.0.0.1 (the local host default
address) and press
Enter
.
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms TTL=###
If there is no reply:
a. Check that the internal cables on the TN802 circuit pack (Notes 4
) have not worked loose.
b. Otherwise, replace the circuit pack.
3. At the command prompt, type ping 10.32.64.97 (the internal IP trunk
server address) and press
Enter
.
■
If configured correctly, the system displays:
Reply from nnn.nn.nn.nn: bytes=32 time <##ms
TTL=###
■
If there is no reply:
— Check that the internal cables on the TN802 circuit pack
(Notes 4 and 6 in
) are not
loose.
— Replace the circuit pack.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...