Maintenance Object Repair Procedures
555-233-123
10-256
Issue 4 May 2002
ATM Cross Talk Test (#1298)
This nondestructive ATM Cross Talk test makes sure that TDM time slots are
correctly allocated to connections. It is useful for diagnosing one-way or noisy
connections. The test fails if the TDM programmable logic and/or the interface to
the DSP is not operating properly. The test can take more than 10 minutes.
Table 10-105.
ATM Crosstalk Test (#1298)
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate required system resources.
Retry the command up to 5 times at 1-minute intervals.
1002
ABORT
Could not allocate time slots. Traffic could be heavy or time slots
could be out-of-service.
Identify and correct TDM-bus errors (if any) using the
procedures in the TDM-BUS (TDM Bus) maintenance object.
Repeat the test up to 5 times at 1-minute intervals.
1003
ABORT
Could not allocate a tone receiver. Too few tone detectors
installed or tone detectors out-of-service.
Identify and correct any TTR-LEV (TTR Level) errors listed in the
Error Log.
Resolve any TONE-PT (Tone Generator) errors listed in the
Error Log.
Retry the test up to 5 times at 1-minute intervals a maximum.
2000
ABORT
Test timed out.
2100
ABORT
Could not allocate required system resources
Retry the command 5 times at 1-minute intervals.
1962
ABORT
All TALKER DSPs are busy.
2302
ABORT
Inconsistent uplink message from the ATM-TRK circuit pack.
Retry the command up to 3 times at 1-minute intervals.
2752
ABORT
The circuit pack in this location is not a TN2305A/2306A.
1-8,
None
FAIL
ATM-TRK circuit pack writing on unauthorized TDM time slots.
The error code indicates the number of TALKER DSPs that are
at fault. These DSPs cannot be used again until this test of the
ATM DSP Test (#1293) tells the circuit pack to use them again.
Retry the command up to 3 times at 1-minute intervals.
If the failure persists, replace the circuit pack.
1-8
PASS
ATM-TRK circuit pack not talking to un-authorized time slots on
the TDM bus. The error code indicates the number of TALKER
DSPs tested.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...