Maintenance Object Repair Procedures
555-233-123
10-1412
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. System Technician has busied out the CDR link to out-of-service state. The
CDR link is torn down.
b. Link Retry Test (#215) fails. The Aux Data field contains either the Channel
ID of Data Channels on the TN777 circuit pack (that is, 3 for Channel 01, 4
for Channel 02, 5 for Channel 03, 6 for Channel 04, and 9 for EIA port) or
an Error Code of 99 indicating that no data channels are available for
setting up the link, or an Error Type of 255 indicating an internal system
error. Refer to the preceding
‘‘Procedures for Restoring the CDR Link’’
for
resolution.
Table 10-528.
CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test cdr-link
primary|secondary sh
18 (a)
0
busy out cdr
WARNING
OFF
release cdr-link
primary|secondary
primary|secondary
25 (b)
0
3 to 6
9
99
255
Link Retry Test
(#215)
MINOR/
WARNING
2
2
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
OFF
test cdr-link
primary|secondary l
513 (c)
0
3 to 6
9
test cdr-link
primary|secondary
1025 (d)
1281 (e)
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...