busyout port
Issue 4 May 2002
8-15
555-233-123
busyout port
This command places the specified port on a circuit pack in a maintenance busy
state. No periodic or scheduled tests are performed on the busied out port until it
is released. When the object is maintenance busy, it is deactivated (no call
processing activity may include the busied object). Warning alarms (error type 18)
are generated on each busied out maintenance object, so that INADS can
determine the state of the objects. The release port command reactivates the
administered port on a circuit pack at a specified location.
Output
The following example is a display of the busyout port command.
Field descriptions
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
busyout
port
location
Port location: PPsspp
Examples:
busyout port 01c1101
busyout port 02c1501
init
inads
craft
none
see below
Port
Port address (cabinet-carrier-slot-circuit)
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station
extension
trunk
xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
Maintenance
Name
Type of busied out maintenance object.
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer
to the detailed list of codes by test number for each MO.
busyout port 01C0701 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C0701 ANL-LINE PASS
Command successfully completed
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...