SYS-PRNT (System Printer)
Issue 4 May 2002
10-1607
555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to address, always
investigate errors in the order they are presented in the table below. By clearing
error codes associated with the Link Retry Test, for example, you may also clear
errors generated from other tests in the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
The Link Tear Down Test disconnects the existing link between DEFINITY
Generic 1 and the external SYS-PRNT output device. If the link has been
disconnected already, this test just returns PASS. All resources allocated for a
System Printer Link are released after this test.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
Link Tear Down Test (#213)
X
D
Link Retry Test (#215)
X
X
ND
Link Tear Down Test (#213)
X
X
ND
Table 10-593.
TEST #213 Link Tear Down Test
Error
Code
Test
Result
Description/Recommendation
40, 50
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 2
times.
1010
ABORT
The System Printer Link has been busied out.
1. Enter release sp-link to release the System Printer Link
from the busyout state.
2. Reissue test sp-link long to execute the test.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 2
times.
PASS
The System Printer Link is torn down or a Short Test
Sequence was executed and the link was not torn down.
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...