PR-MAINT (Maintenance Processor)
Issue 4 May 2002
10-1389
555-233-123
MTP Outpulse Relay Test (#102)
This test is a nondestructive test. The test validates the correct operation of the
remote access CO trunk used by INADS. The MTP first goes off-hook, then
on-hook on this trunk. If the loop current is detected, the test passes. This test is
not allowed if the remote access line is in use.
10106
FAIL
The Maintenance/Tape Processor was reset, but it
responded with a NOT PASS status, indicating that it did not
pass initialization correctly. The MTP is not functioning
correctly. The system should continue to function, but it will
not have the ability to save translation to tape, or to read tape
if the system needs to be rebooted. Environmental monitoring
is lost, as is communication with the Standby Processor.
1. Retry the command at 1-minute intervals a maximum of
5 times.
2. If test continues to fail, replace the Processor circuit
pack.
PASS
The Maintenance/Tape Processor was reset, and it passed
initialization correctly. The other MTP tests should be
examined to verify that the MTP is functioning correctly.
1. Enter test processor a/b and verify that the MTP is
functioning correctly.
Table 10-515.
TEST #101 MTP Reset Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...