RDIG-STA (Remote Digital Station)
Issue 4 May 2002
10-1451
555-233-123
l. Error Type - 3840; with aux data 40965 — indicates that no terminal is
connected to the COMBO board. No maintenance action is required. This
is also the code that is generated when the link between the circuit pack
and the voice terminal is successfully reset. No craft action is necessary.
Error Type - 3840; with aux data 40989 — indicates an uplink message has
been logged indicating that the Electric Power Feed (EPF) is on with no
load on it. No action is necessary. No craft action is necessary.
m. Error Type - 3841 — The circuit pack’s message buffer is full. This may be
caused by having many display phones with heavy traffic connected to the
circuit pack. No action is necessary.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Digital Line Electronic Power Feed Test, for
example, you may also clear errors generated from other tests in the testing
sequence.
Digital Line Electronic Power Feed/Positive
Temperature Coefficient/PPF Test(#11)
This is an Electronic Power Feed (EPF) restoration test. In this test, the processor
requests that the EPF be turned on for a given port, and an attempt is made to
turn on the power supply to the station. If no current is drawn, the station is
probably not connected. If an overcurrent condition is sensed, there may be a
short in the loop. A message is returned reporting that either the EPF was
successfully turned on, or that an overcurrent condition was sensed. This test is
repeated again 5 seconds later.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/
ND
1
1
D = Destructive; ND = Nondestructive
Digital Line Electronic Power Feed Test (#11)
X
ND
DIG-LINE Station Lamp Updates Test (#16)
X
X
ND
Station (Digital) Audits Test (#17)
X
X
ND
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...