
TONE-PT (Tone Generator)
Issue 4 May 2002
10-1809
555-233-123
1022
ABORT
[G3r V2] Tone detection for the system is administered as
wide broadband (tone detection mode 5), and the Tone
Detector used for this test was not a TN420C or TN2182 (the
only circuit packs with this capability). GPTD ports on other
types of Tone Detector circuit packs are taken out of service
since they cannot provide the administered function.
1. Change the tone-detection mode administered on the
system-parameters country-options form
Or
2. Remove all non-TN420C and non-TN2182 circuit packs
from the system.
2000
ABORT
Response to the test request was not received within the
allowable time period. System resources required for this test
are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, follow normal escalation
procedures.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, follow normal escalation
procedures.
1 (a)
FAIL
DTMF generation failed for the active tone generator.
105 (a)
FAIL
Generation of 440-Hz failed.
109 (a)
FAIL
Generation of 2225-Hz failed.
110 (b)
FAIL
Generation of 404-Hz level invalid.
111 (b)
FAIL
Generation of 1004-Hz low level invalid.
112 (b)
FAIL
Generation of 1004-Hz high level invalid.
113 (b)
FAIL
Generation of 2804-Hz level invalid.
115 (b,c)
FAIL
Generation of digital count sequence invalid.
120 (a)
FAIL
Generation of quiet tone failed.
1044 (a)
FAIL
DTMF generation failed to generate Digit 1 for the standby
tone generator.
Table 10-657.
TEST #40 Tone Generator Transmission Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...