Maintenance Object Repair Procedures
555-233-123
10-1254
Issue 4 May 2002
Error Log Entries and Test to Clear Values
Table 10-469.
PI-SCI System Communication Interface Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/
Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test interface PCS sh r 1
1 (a)
2055
2056
2057
2058
none
none
none
none
257 (b)
Any
none
MAJOR
ON
test interface PCS l
2
2
See WARNING below.
!
WARNING:
The “test interface long” command resets the PI-BD and causes all ISDN-PRI and
BX.25 links to come down.
769 (c)
Any
none
MAJOR/
WARNING
3
3
Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
OFF
test interface PCS l
1025 (d)
Any
none
MAJOR/
WARNING
OFF
test interface PCS l
1281 (e)
Any
Sci Start Test (#176)
MAJOR/
WARNING
OFF
test interface PCS l
1793 (f)
Any
none
MAJOR
ON
test interface PCS l
2049 (g)
90xx
Sci Start Test (#176)
MAJOR
ON
test interface PCS l
2305 (f)
Any
Sci Self Test (#231)
MAJOR
ON
test interface
PCS sh r 2
2561 (h)
Any
none
MAJOR/
WARNING
OFF
test interface PCS l
2817 (i)
Any
none
MAJOR/
WARNING
OFF
test interface PCS l
2818 (j)
Any
none
MAJOR/
WARNING
OFF
test interface PCS l
3073 (f)
Any
none
MAJOR/
WARNING
OFF
test interface PCS l
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...