Maintenance Architecture
555-233-123
1-2
Issue 4 May 2002
Alarms are further classified as:
■
On-board problems originate in the circuitry on the alarmed circuit pack.
■
Off-board problems originate in a process or component that is external to
the circuit pack.
To clear system alarms using the appropriate maintenance book:
1. Type display alarms and press
Enter
.
2. A query screen appears (
), where you can chose if you want to
see all alarms or if you want to restrict the list to certain kinds of errors.
Screen 1-1.
Alarm Report query screen
Table 1-1.
Alarm levels, reporting conditions and action to take
Alarm
level
Description
Reported
to
INADS?
Reported
to
console?
What action to take?
MAJOR
Critical service
degradation
Y
Yes, after 4
attempts to
call INADS
Immediate attention
MINOR
Some service
degradation but does not
render the system
inoperable.
Y
Same as
above
Check to see what service
is affected
WARNING
Failure that causes no
significant service
degradation
N
1
1.
Some system-downgraded Warning alarms are reported to INADS.
N
Monitor the situation. May
be service or equipment
interruption or failure
outside the switch.
ALARM REPORT
The following options control which alarms will be displayed.
ALARM TYPES
Active? y Resolved? n
Major? y Minor? y Warning? y
REPORT PERIOD
Interval: m From: / / : To: / / :
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet:
Port Network:
Board Number:
Port:
Category:
Extension:
Trunk ( group/member ): /
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...