MODEM-PT (Modem Pool Port)
Issue 4 May 2002
10-1105
555-233-123
Modem Pool Conference Test (#97)
This test is destructive.
This test checks most of the switching and gain control functions provided by the
NPE circuit in the analog section of the conversion resource. This test
conferences a 1004-Hz tone through the NPE, looping it back so that it can be
verified with a Tone Detector circuit.
ANY
FAIL
The NPE of the tested port was found to be transmitting in
error. This condition causes noisy and unreliable
connections.
1. If the remaining ports are currently not in use (that is,
yellow LED is off), attempt to reset the circuit pack.
Then repeat the test.
2. If the test fails again, replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated
using other port tests and by examining station, trunk, or
external wiring.
Table 10-416.
TEST #97 Modem Pool Conference Test
Error
Code
Test
Result
Description/Recommendation
ABORT
System resources required for this test are not available.
1000
ABORT
System resources required to run this test are not available.
The port may be in use on a valid call. Determine whether
the port is available for testing.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to TDM-BUS (TDM Bus) Maintenance documentation
to diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors and is not
handling heavy traffic, repeat the test at one-minute
intervals a maximum of 5 times.
Continued on next page
Table 10-415.
TEST #96 Modem Pool NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...