Maintenance Object Repair Procedures
555-233-123
10-420
Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Values
Table 10-158.
DS1 CO Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/
Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test trunk <grp>/<mbr>
1 (a)
57408
1 (a)
57487
15 (b)
Any
Port Audit and
Update Test (#36)
18 (c)
0
busyout trunk
<grp>/<mbr>
WARNING
OFF
release trunk <grp>/<mbr>
130 (d)
None
WARNING
ON
test trunk <grp>/<mbr>
257 (e)
57392
DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
2
This alarm will only be raised when the System-Parameter Country form has the Base Tone
Generator field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this
trunk group are out of service, then the alarm will be upgraded to a MAJOR alarm.
OFF
513 (f)
57393
DS1 CO Dial Tone
Seizure Test (#314)
MIN/MAJ
2
OFF
769 (g)
57484
1025
DS1CO Dial Tone
Seizure Test (#314)
WARNING
OFF
test trunk <grp>/<mbr>
1281
Conference Circuit
Test (#7)
MAJ/MIN/
WRN
3
3
Minor alarms on this maintenance object (MO) may be downgraded to Warning alarms based on
the values used in the set options command. If the Minor alarm is not downgraded by the set
options values, the Minor alarm is upgraded to a Major alarm if 75 percent of the trunks in this group
are alarmed.
ON
test trunk <grp>/<mbr> r 4
1537
NPE Crosstalk Test
(#6)
MAJ/MIN/
WRN
3
ON
test trunk <grp>/<mbr> r 3
1793 (h)
ON
test board PCSS l
2562(i))
16665
2817(j)
52992
3840 (k)
Port Audit and
Update Test (#36)
Continued on next page
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...