Maintenance Object Repair Procedures
555-233-123
10-298
Issue 4 May 2002
When this error occurs for an ASAI or Avaya adjunct, the service technician
should:
1. Execute the test station extension command, paying particular
attention to any tests which fail, and perform the associated repair
procedures for those tests.
2. Check the health of the adjunct by following the recommended
repair procedures of the manufacturer of the adjunct if the preceding
step does not resolve the problem.
3. The alarm condition persists and, if the above steps do not resolve
the problem, follow normal escalation procedures.
d. This error and associated WARNING alarm are logged against an ASAI or
Avaya endpoint when the adjunct has asked the switch to suspend
Maintenance on the ASAI or Avaya endpoint. Busying out and releasing
the ASAI station or ADJLK station will clear this alarm.
e. This error occurs when the endpoint sends more messages than the switch
can handle. The switch suspends the reception of messages from the
endpoint for a short period of time. There is no repair procedure for this
error. If the condition persists, replace the endpoint.
f. This error occurs when the signaling link associated with a BRI endpoint
has too much link establishment related traffic. This could occur if the
signaling link is bouncing between assigned and established states.
Software will suspend activity to this endpoint for 75 minutes when the
endpoint is alarmed due to this problem (note that service suspension does
not occur if the endpoint is an ASAI or Avaya adjunct). If this problem
persists, replace the endpoint. If replacing the endpoint does not fix the
problem, follow normal escalation procedures.
g. This error occurs when the ASAI-ADJ or ATT-ADJ or LGATE-AJ or
ATTE-AJ message is not transmitted because the PKT-CTRL (Packet
Control Circuit Pack) transmit buffers are exhausted. Frequent or
persistent occurrence of these events may indicate a hardware problem or
traffic overload on the PKT-CTRL, the signaling link, or the ASAI or Avaya
adjunct. Attempt to resolve the problem by following the repair procedures
for the PKT-CTRL. If these attempts fail, the problem should be escalated
because re-engineering of the traffic on the PKT-CTRL, signaling link, or
adjunct may be necessary.
h. This error occurs when the ASAI message is not transmitted because the
transmit buffer for the ASAI link is full, causing the link to be flow controlled.
Frequent or persistent occurrence of these events may indicate a hardware
problem or traffic overload on the PKT-CTRL, the signaling link, or the
ASAI or Avaya adjunct. Attempt to resolve the problem by following the
repair procedures issued by the manufacturer of the adjunct. If these
attempts fail, the problem should be escalated because re-engineering of
the traffic on the PKT-CTRL, signaling link, or adjunct may be necessary.
Содержание Definity SI
Страница 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Страница 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Страница 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Страница 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Страница 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Страница 2763: ...VC DSPPT Issue 4 May 2002 10 1977 555 233 123 Figure 10 107 VC Circuit Pack DSP Port Local TDM Loopback Test...
Страница 2776: ...Maintenance Object Repair Procedures 555 233 123 10 1990 Issue 4 May 2002 Figure 10 109 VC Circuit Pack Summer Port Loopback Test...
Страница 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...
Страница 2968: ...Index 555 233 123 IN 10 Issue 4 May 2002...